Things You'll Need
Instructions
Connect the positive terminal of the function generator output to the positive terminal of the diode. Connect the negative terminal of the function generator output to the negative terminal of the diode.
Connect one of the oscilloscope inputs across (parallel to) the positive and negative terminals of the diode.
Switch on the function generator, set it to output a square wave, and set an amplitude within the limits of the diode. Check the diode specification sheet to check the available voltage ranges. Set a desired frequency on the function generator.
Switch on the oscilloscope. Change the volts/division and time/division settings until the waveform comes into view on the oscilloscope screen. The frequency response of the diode can now be measured by changing the frequency output on the function generator and viewing the waveform on the oscilloscope screen.